Practical Grounding, Bonding, Shielding and Surge Protection Course
Electrical and Power Engineering
Select Other "city & date"
Practical Grounding, Bonding, Shielding and Surge Protection Course
Course Overview:
This comprehensive course focuses on grounding and bonding electrical systems, emphasizing national standards, practical methods, and surge protection.
Participants will learn about earthing systems, soil investigation for grounding, grounding design, and noise mitigation in industrial and sensitive electronic environments.
Topics include lightning and surge protection, special considerations for hazardous areas, and ground system inspections. Ideal for engineers, technicians, and safety professionals, this course equips attendees with the knowledge to enhance system safety, reduce noise interference, and protect against surges and transient issues in electrical systems. Practical examples and calculations enrich the learning experience.
Course Objectives:
Upon the successful completion of this course, each participant will be able to:-
- Apply the various methods of grounding electrical systems
- Detail the applicable national Standards
- Describe the purposes of grounding and bonding
- List the types of systems that cannot be grounded
- Describe what systems can be operated ungrounded
- Correctly shield sensitive communications cables from noise and interference
- Apply practical knowledge of surge and transient protection
Who Should Attend?
This course is intended for Building Service Designers, Consulting Engineers, Data Systems Planners and Managers, Electrical and Instrumentation Technicians, Electrical Contractors, Electrical Engineers, Electrical Inspectors, Instrumentation and Control Engineers, Maintenance Engineers, Power System Protection and Control Engineers, Project Engineers, Safety Professionals.
Course Outlines:
Network Structures
- Structure of Distribution Networks
- The Supply Source
- MV Power Supply
- Different MV Service Connections
- LV Networks inside the Site
- LV Switchboards Supply Modes
- LV Switchboards Backed up by Generators
- LV Switchboards backed up a UPS
Earthing System
- The need for Earthing Systems
- Step and Touch Voltage
- Earthing System at Low Voltage
- Medium Voltage Earthing System
- Limiting Resistance Earthing
Soil Investigation
- Soil Characteristics
- Soil as a Grounding Medium
- Effect of Voltage Gradient
- Effect of Current Magnitude
- Effect of Moisture, Temperature and Chemical
- Use of Surface Material Layer
- Soil Structure and Selection of Soil Model
- Investigation of Soil Structure
- Classification of Soils and Range of Resistivity
- Resistivity Measurements
- Interpretation of Soil Resistivity Measurements
Earthing System Design
- Simple Earthing System Design
- Earthing System Components
- Ground Roads
- Bar Wiring
- Clamping o Welding
- Techniques for Ground System Construction
- Ground Resistivity Measurements
- Ground System Resistivity Measurements
- Bonding
- High-Frequency Bonding and “Grounding”
- Sample Calculations
Grounding of Electronic Equipment
- Electrical Power System Selection Consideration
- Equipment Selection and Installation Considerations
- Grounding Considerations
- 380 Hz to 480 Hz System
- Industrial System Noise Considerations
- Industrial System Grounding Practices
Lightning Protection
- Integral Protection System
- Construction Protection Classes
- Accessories and Equipment
- Grounding Consideration or Lightning Protection
- Separately Mounted Protection Systems
- Overhead Ground Wire Type
- Waveguide Installation and Grounding
- Lightning Generated Transient Surge Protection
- Transient Source and Equipment Damage
Surge Protection
- Surge Definition
- Bonding as a means of Surge Proofing
- Surges and Surge Protection
- Surge Protection of Electronic Equipment
- Achieving graded Surge Protection
- Positioning and Selection of Lightning/Surge Arrestor
- Surge Protection for Sensitive Equipment
Noise Mitigation
- Electrical Noise and Measures for Noise Reduction
- Earth Loop as a Cause of Noise
- Ways in Which Noise Can Enter a Signal Cable
- Shielded Isolation Transformer
- The Use of Insulated Ground (IG) Receptacle
- Zero Signal Reference Grid and Signal Transport
- Harmonics in Electrical Systems
Special Considerations
- Industrial Hazardous Areas
- Insulation Monitoring
- Ground Fault Protection
- Ground System Inspection